10-22-08 Site Strategy

1 comments:

October 23, 2008 at 10:57 PM Michael Kubo said...

Dan,

The site plan is only a starting point in catching up with the development of your project. But you know pretty clearly that much more needs to be done given where you are at. At this point you should be developing plans of the different floors, sections, 3D representation through models or renderings, etc. This is the only way you can dissect your system and see how it can perform as a building organization—what works and what does not. Right now you are still stuck "outside" of the building in the same way you were with the earlier model studies; the site plan does not help produce much more information about it, and so you are left with essentially the same geometry you had before in the models. Given how far behind the project is, it is disappointing to see only one drawing submitted, rather than an attempt to quickly build up more knowledge about the project by working across plan, section, views, etc., in a way that would force the overall geometrical system to change or become more specific. You will certainly need all of this documentation for the midreview next week, and not producing them now means losing an opportunity to test them (and have our comments) before you present to outside critics.

Given the lack of documentation, it is difficult to comment more on the specifics of the project itself, other than to say it needs more information to judge. It looks like there is a gradient between more public programs (visitors center, cafeteria) and more private areas (office, research), but this needs to be made explicit in developing the plans. Why is one ratio of solid to void (holes) better for one program versus another? If the public-to-private programs are organized along a more or less linear gradient, what happens in the middle area of the plan where the interior spaces become radically thinner and the circulation bottlenecks? You need to fill in information at a finer scale (space planning module, structural module, circulation pathways, etc.) that can give meaning to the shapes your system produces. It is also totally unclear what happens in section since you have not drawn one.

What is a "decompression space?" I am not sure what you mean by these, especially since they refer to two different spaces ("decompression" in the middle, "internal decompression" at the edge of the building) that look totally different in plan. If there is a diagram of the intended relation between different program areas and the role of these decompression zones, this also needs to be produced.

Please post your missing documentation (plans, sections, renderings) immediately as you produce it over the next week. I will be checking the website for these new drawings.